WEBWAYONE LTD, Unit 11 Kingfisher Court
Hambridge Road, Newbury, Berkshire. RG14 5SJ
00 44 1635 231 514 support@webwayone.co.uk
Protocol options menu
=====================
1. Modem init string : AT&K0&DE1V1Q0S0=0S7=10
2. Modem dial string : ATD
3. Modem hangup string : ATH
4. Modem connect string :
5. CLID string 1 : 00001
6. CLID string 2 : 00002
7. Baudrate RS-232 port : 9600
8. Baudrate V31bis port : 9600
0. Back to main menu
+. Next page
-. Previous page
Make your choice:
Select 5: CLID string 1 and set to '00001'
CLID string 1: 00001
Press Enter key
Select +
Protocol options menu
=====================
1. One account per call : Yes
2. One event per block : Yes
3. Three digit event numbers : No
4. Text in SIA : Yes
5. PA auto-restore : No
6. Dual reporting : No
7. Auto dial : No
8. PC calls : Yes
9. Protocol : V24
0. Back to main menu
+. Next page
-. Previous page
Make your choice:
Select 1: One account per call
One event per block (Y/N):
Select Y
Do the same for 2: Select ‘Y’ for One event per block
Do the same for 4: Select 'Y' for Text in SIA
Do the same for 8: Select 'Y' for PC calls
Select +
Protocol options menu
=====================
1. Wait for modem reply : 005
2. Wait for modem dial reply : 010
3. Wait for redial : 015
4. Max dial attempts/CS : 240
5. Max modem command attempts: 003
6. Event delay : 020