Galaxy 16 PLUS alarm panel connections and configuration
To install the Galaxy 16 Plus for full remote management you will require the Dial Capture Module (DCM).
Connect the WebWay Dial Capture Module (DCM) panel interface A and B to the Galaxy 16 Plus connection telephone
terminals labelled A and B.
Connect the WebWay PWR + and - to the terminals AUX+ and AUX- (Labelled ‘Auxiliary 12V Power Outputs’ in the
Galaxy 16 Plus Engineers Manual PCB layout).
Galaxy 16 PLUS panel configuration
Enter Engineering mode
Go to Menu 12 Comms 1
Enter Account number <_______> Site ID (Menu 1)
Enter telephone number 1 <01666111> (Menu 2)
Select Format (Menu 4)
Select SIA
Note: it is recommended that the additional Triggers are selected (Menu 7):
Select 4 < (black square) Set/Reset>
Select Access (Menu 10)
Select <Direct>
Go to Menu 13
Select < 01 = NO. OF RINGS>
Set NO. OF RINGS to 01
Escape to engineer mode finish. Note that as this is using a dialler no modules will be found by the Galaxy.