Guardall alarm panel connections and configuration
WebWay communicators/SPTs are connected to alarm panels in order to enable fast and secure transmission of
detailed alarm messages using WebWays unique Virtual Private Security Network (VPSN). The communicators provide
further benefits to installers including carrying out remote upload/download (when possible with the panel range) whilst
simultaneously sending alarms and network availability monitoring of each connection using WebWay’s unique Network
Quality of Service analytics (NQoS). All communicators are certified by the British Research Establishment and the Loss
Prevention Certification Board and are accepted by all insurance companies.
Integration Requirements:
Serial
DCM
Panel Ranges Supported
RX16i, QX 32i, QX 18, QX18i, QX34, QX34i,
PX18, PX34, PX48i, PX80, PX80i, PX250HS,
PX500
RX16i, QX 32i, QX 18, QX18i, QX34,
QX34i, PX18, PX34, PX48i, PX80,
PX80i, PX250HS, PX500
Panel Modules Required
No modules required (all integrated):
RX16i, QX32i, QX18, QX18i, QX34, QX34i,
PX48i, PX80i
No modules required (all integrated):
RX16i, QX32i, QX18i, QX34i, PX48i,
PX80i
Guardall RS232 serial module is required
on: PX500, PX250HS, PX18, PX34, PX80
Guardall external dialler module is
required on: PX500, PX250HS, QX18,
QX34, PX18, PX34, PX80
Panel Software Required
V4.20
V4.00
SPT Modules Required
None
Dial Capture Module (DCM)
SPT Cables Required
Guardall Serial Cable 05-5032, Power
source (12V/24V)
Cable pair for dialler, Power source
(12V/24V)
SPT Firmware Required
V3.36 (minimum), V3.41 (recommended)
V3.40
Panel UDL Software Required
GSR (any version)
GSR (any version)
WebWay UDL Software
Required
Remote Manager V2.1.1.1 or higher
Remote Manager V2.1.1.1 or higher
Additional Requirements
Guardall GSR Serial Dongle*
Guardall GSR Serial Dongle*
* Please be aware this needs configuring the the WebWay SPT and the Guardall panel
UDL (Upload/Download) description
When connected to a WebWayOne communicator Remote Access will be possible into the alarm panel. The tools
required are detailed above and the panel configuration is detailed later in this document. In effect for both alarms and
UDL the WebWay SPT is taking the place of a GSR module. There are strict security controls in place with the system
where the only access possible is via the secure VPSN that a WebWay provides. Authorisation for access must be
approved by the ARC involved and only those using the WebWay Remote Manager software will be able to gain access.
On top of this there are the usual security methods in place that a GSR connection would have you need to have a
GSR dongle and a valid copy of the UDL software.
*Contact Product Support for more information. Please note-Remote Manager Software is always required for UDL.
Connection of the SPT to the Guardall:
Connect the 9 way connector cable to the Guardall RS232 port on either the main board assembly or the external RS232
module and the cable wires to the WebWay SPT as detailed in the table below.
Important: Please note which Serial module you have connected to (if there are multiple) in order to make sure the panel
programming matches.
Please Note: For a serial connection the GSR dongle Serial number needs configuring in the WebWay SPT as well as
in the alarm panel. This can be done through menu G in the same manner as for “Auto Take-On” which uses menu D.